Rules And Practice For Adjusting Watches - LightNovelsOnl.com
You're reading novel online at LightNovelsOnl.com. Please use the follow button to get notifications about your favorite novels and its latest chapters so you can come back anytime and won't miss anything.
In placing limits of allowance for variation in various grades it is not intended that all watches of a particular grade will have the extreme variation. It is possible that an individual watch in the twenty-five seconds allowance cla.s.s may have an even better rate than another watch that is in the six seconds cla.s.s. It is also possible for a watch in either cla.s.s to have a perfect rate, although these would be rather exceptional instances.
24. _Some Necessary Requirements for Learning Adjusting._
The adjustments to isochronism and positions are not permanent to the same extent that the temperature adjustment is, and they can be damaged or destroyed entirely by the average workman in making ordinary repairs unless he is familiar with the common principles governing their production and maintenance.
Experienced workmen who are familiar with these principles avoid unconsciously doing any damage and make practical repairs in a manner that will maintain or improve the original adjustment and time-keeping qualities of the watch.
To know and to make use of these principles does not make a "putterer"
of the workman, in fact the consequence is just the reverse, because the training acquired tends to eliminate guess work and enables him to determine more readily as to just what the trouble may be, how to correct it, and as to just what degree of perfection is required in a particular instance.
Certain practical requirements are necessary in reaching this standard of workmans.h.i.+p and it would not be profitable to attempt to do adjusting unless one has first had a reasonable degree of training as a watchmaker or repairer, especially in such branches of the work as truing and poising balances; truing, leveling and centering hairsprings; matching the escapement; finis.h.i.+ng pivots, and properly cleaning and a.s.sembling watches.
These mechanical requirements and experiences alone are not sufficient, however, and a certain amount of study must be consolidated with them in order to become proficient. This study should not deal so much with the problems of manufacture of the watch, or its various parts, as it does with the problems pertaining to the finished results that are to be obtained through refinement and intelligent a.s.sembly of these parts. The workman's willingness to indulge in such study is a very large a.s.set among the requirements, and it only remains for him to obtain the proper cla.s.s of instruction and then to conscientiously follow correct methods in his practice and to make personal experiments, conforming to the instruction, so that his confidence will become more enduring.
It is further required that he be capable of realizing the difference between genuine and imitation materials, especially such essentials as balance staffs, hole jewels, mainsprings and roller jewels, which are the most frequently changed and most frequently subst.i.tuted parts of watches. Imitation materials may be less expensive as a matter of first cost but staffs may have pivots and shoulders out of line, or out of true; hole jewels may be rough, out of round or extremely thick; mainsprings soft, or of improper proportion, and roller jewels may have sharp edges which cause rubbing in the fork and "hanging up"
when the second hand is reversed. It is most satisfactory to depend upon the materials supplied by the manufacturer of the watch, as imitation goods are seldom any better.
25. _Train and Escapement Freedom._
Beyond a general insight of high cla.s.s watch-work this book is not intended to meet the requirements of beginners. It is designed princ.i.p.ally for watchmakers of some experience, and cannot presume to cover details that would be essential for those in early apprentices.h.i.+p. It is thought essential, however, to consider some matters in a general way and among these are the subjects of side shakes and end shakes, and the escapement, as far as they pertain to general inspection of the watch without consideration of details that refer to correction of irregularities which are presumed to have been acquired in earlier training.
Thoroughness of mechanical ability always demands a system of inspection and of making corrections and it is quite necessary to follow some method that will reveal any point or points that may not be up to standard.
As a rule it is best to begin at either end of the watch, and if it is to be taken down the best place to begin is usually with the balance and examine each part as it is removed until the barrel has been reached. If it is not to be taken down, just as good results will be obtained by beginning the examination at the barrel and finis.h.i.+ng with the balance. Sometimes watchmakers of considerable ability will demand as a basic consideration that pivots be fitted with very little side shake and that end shakes also be quite close if close time is to be expected.
These presumed to be, wide side shakes and long end shakes, very often have nothing whatever to do with the absence of a close position rate and frequently are absolutely necessary for good performance of the watch and proper s.p.a.ce for oil.
The importance of reasonable limits is of course granted, but it is very detrimental to have pivots too close fitting and more stoppage and irregular time keeping can be traced to lack of freedom than can be traced to excessive shakes.
If the repairer is not familiar with accepted standards of side and end shakes, he can improve his judgment by examining watches of the higher grades and comparing the results with those found in cheaper makes of watches.
Such examination will invariably disclose the fact that fine watches receive very careful consideration in this respect. The center, third and fourth wheels generally having from 0.03 mm. to 0.05 mm. freedom for end shake and 0.015 mm. to 0.02 mm. for side shake. The escape wheel, pallet and balance will be found to run quite uniform at from 0.02 mm. to 0.03 mm. freedom for end shake and from 0.0075 mm. to 0.0125 mm. for side shake. The smaller and thinner watches generally favoring the lesser figures and the larger and thicker watches favoring the higher.
This uniformity of freedom will be found absent in cheaper watches; for instance, a center wheel may have 0.02 mm. end shake and 0.01 mm.
side shake which would be very close fitting for large pivots. The fourth wheel may have as much as 0.08 mm. end shake and 0.03 mm. side shake which would be too great. The pallet may have 0.05 mm. end shake and the balance 0.01 mm. and in this instance the short end shake of the balance would be more detrimental in most instances than would the longer end shake of the pallet. The variation will even be found to exceed these figures and when they are found in connection with thick, straight hole jewels they often interfere with a close position rate and with regularity of time in service. The interference in timekeeping is considerably aggravated in cases where one pivot has excessive side shake and the opposite pivot is close fitting, as this tends to cause almost certain binding of the close fitting pivot as soon as the power of the mainspring is applied.
The end shake and side shake allowance for the barrel depends considerably upon its style of construction. Safety barrels constructed so that the arbor revolves with the main wheel, when the watch is running, may have about the same end shake and side shake as applied to the center, third and fourth wheels, and if the pivots of the arbor are quite large they may have a trifle more side shake.
As a rule larger pivots will stand more side shake than smaller pivots; this, however, does not apply in the case of large bearings, such as safety main wheels that revolve around a stationary arbor, or going barrels where the entire barrel revolves around the stationary arbor when the watch is running.
In such instances the main wheel or barrel should have from 0.03 mm.
to 0.05 mm. end shake on the arbor and should be just free for side shake.
The arbor which turns only when the watch is wound requires merely freedom for end shake between the plates, as well as for side shake where the pivots pa.s.s through the plates.
With reference to the escapement, good watchmakers often have different methods of examining the various points and of making corrections and it is not of so much importance as to just how correct conditions are obtained, as it is that they actually be obtained.
Whatever the method may be it is certain that each escape wheel tooth must have positive locking on each pallet stone and that there must be positive s.p.a.ce for drop between the back of each stone and the pointed end of each escape wheel tooth. There must also be sufficient draw when each tooth and stone are locked to hold the fork against the bankings.
When the lock, drop and draw are correct it is next necessary to see that the fork length and guard pin freedom are correct.
There is only one positive method of determining as to when the fork length is correct, and this is through closing the bankings to drop.
This can be done either before or after placing the balance in the watch and merely requires turning the banking screws so that the excentric pins will close in on the fork until the fork arrives at the pins, at the same instant that the tooth drops on the pallet stone.
This eliminates any slide of the stone on the tooth beyond the actual locking and in this condition it is required that the roller jewel pa.s.s through the fork slot and out of the fork horn entirely on both sides with perfect freedom.
Should it touch on both sides of the fork, then the fork is either too long or the roller jewel is too far forward, and if it touches on one side only it may require simply equalization of the freedom. The guard pin length also must be obtained with the bankings closed to drop and should be just free from the safety roller on both sides.
When the inspection proves that these conditions have been properly provided for, it is necessary to slightly open the bankings so that there will be just a trifle of slide of each stone, on each tooth, after the locking takes place.
Extremely wide side shakes of the escape, pallet or balance pivots will sometimes cause striking of the roller jewel when conditions are otherwise correct, and these side shakes should not be very much beyond the extreme limits mentioned in this number. The fact of this feature, however, should not be construed as a recommendation that these pivots be closely fitted, for reasonable freedom is to be desired because it is positively necessary.
CHAPTER VII
THEORY AND PRACTICE
26. _Theory of Frictional Errors and the Isochronal Hairspring._
Theory teaches us in brief, that the position adjustment is made necessary princ.i.p.ally because of frictional errors. It would therefore seem that if the watch was mechanically correct there would be little or no requirement for position alterations.
We are also advised that an isochronal hairspring is one which will cause the long and short arcs of the balance to be made in equal time and that to attain this, the center of gravity of the spring must coincide with the center of gravity of the balance and that a certain pinning point is necessary in producing this result.
Now if we have a watch of correct mechanical construction and fitted with an isochronal spring it would seem that a close rating timepiece would be a.s.sured.
27. _How Theory Works Out in Practice and What Isochronism Consists of._
Practical adjusting, however, proves that such is not the case, for even when the construction and alterations produce watches as nearly correct as scientific methods can determine, there is often considerable variation in the position rates. A twenty-four hour test in any position may prove that the long and short arcs are made in equal time showing the spring to be isochronous and yet the position variations have not been accounted for. In this connection experience proves that a spring showing a perfect isochronal rate may have its collet pinning point changed, in relation to the pinning point at the stud and that through such an alteration, a correction in positions can be obtained, without in the least disturbing the perfect isochronal rate.
This indicates that the separation of the two adjustments which is possible in theory, does not hold good in practice, because a spring showing a perfect isochronal rate has been altered for the purpose of counteracting some position error and thereby producing a practical center of gravity of the balance and spring combined, instead of separately.
This may be further explained as creating an error in a spring which is supposed to be theoretically isochronous, with the idea of making it act in opposition to the position error and the combination thus obtained produces practical isochronism as well as a corrected position rate.
It is not suggested that these relative pinning points be altered for the purpose of overcoming position variation such as may be caused by dirt and gummy oil, damaged pivots, or balances that are out of poise.
The watch should be in first-cla.s.s condition and have a good motion in every position and then the alterations may be safely undertaken in accordance with the principles.
Adjusted to isochronism indicates that the watch functions uniformly during the entire twenty-four hours running. It is immaterial as to whether the rate be perfect or whether it be a gain or a loss, so long as it is uniform.
The watch is not isochronous if there is both a gain and a loss in the rate, even though the time be perfect at the expiration of twenty-four hours.
Experiment will demonstrate that watches carefully adjusted to positions will also have a very close isochronal rate. These isochronal experiments can be made by timing watches for twenty-four hours in any one of the vertical positions and noting the variation in periods of from four to twelve hours and by comparing the variation in the first period, during which time the arc of motion is long, with the variation in the latter period when the mainspring power is weaker and the arc of motion is short.